SAVE A LIFE WITH TRUSTED TECHNOLOGY & PROVEN SIMPLICITY

The iPAD SP1 defibrillator is designed with the end user in mind, making it as simple as possible to use.  It uses state of the art technology to save precious seconds when every second counts.

Fully or Semi Automatic - You Decide

semifully

semifully

  • Clear and user friendly to operate and maintain

    Guidance at every step with clear illuminated illustrations, calm voice prompts & large responsive buttons.

  • Pre-connected adult/child “smart” electrode pads

    Pad indicator displays illustrates pad life remaining, with verbal instructions to “replace pads” or to “connect pads”.

  • Simple switch selection from adult to child mode

    The same set of electrode pads for both adults and children.  No additional pads required,  saving precious time and expense.

  • Automatic adjustment to background noise

    Voice prompts can adjust up to 90 decibels, so it can always be heard easily in noisy environments.

  • CPR detection & metronome

    Ensures CPR is being performed, giving an audible guidance to keep chest compressions going at the correct rate.

  • Plug-in pad adapters to stop pad changes when backup arrives

    Pad compatibility with front line vehicles of the NHS Ambulance Services, streamlines the handover to of a patient to advanced care.

iPAD SP1 PACKAGES & ACCESSORIES

Indoor Cabinet with Alarm for the iPAD SP1 Metal Wall Bracket Cradle for the iPAD SP1 iPAD SP1 Lithium-Ion Battery Pack iPAD SP1 Dual Adult/Child Electrode Pads
AED Wall Sign iPAD Electrode Adapters iPAD SP1 Orange Carry Case 2GB SD Card (with software

Standard iPAD SP1 Package

The iPAD SP1 comes as a package to enable you to be ready to save a life in minutes. CLICK HERE for simple step by step instructions of how to set up & use or CONTACT US for guidance.  A standard package includes:

 

sp1_package_cut
    • SP1 Device with Starting 7 Year Warranty

    • Click here to register & upgrade to free 10 year Warranty

    • Two Sets of Adult/Child Electrode Smart Pads

    • LiMnO2 Battery Pack with 4 year Warranty

    • 2 Sets of AED Starter Kits, which Include:

– Nitrile Gloves (Large)

– 2 large dry patient wipes

– Gallant Prep Razor

– CPR Faceshield

– Tuff-Cut Scissors

BoltOns

Additional options are available to augment the above package to suit your needs. Below is a list of additional bolt-ons available for the iPAD SP1. CONTACT US to discuss your requirements. We are here to help.

    • Large range of custom Heavy Duty External Cabinets.

    • Worry Free Package; which includes unlimited replenishments of consumables for the lifetime of your AED*.

    • A choice of Electrode Pad Adapters, for quick patient transfer. Click here for more information

*Selection criteria applies

Device Specifications – Model Name: CU-SP1
Physical
Category Nominal Specifications
Dimensions 260mm x 256mm x 69.5mm (Width x Length x Height)
Weight 2.4kg (Including the battery pack and pads)
   
Environmental
Category Nominal Specifications
Operational Status (The device is in emergency use)
Temperature: 0°C ~ 43°C (32°F ~ 109°F)
Humidity: 5% ~ 95% (non condensing)
Standby Status (The device is stored together with the defibrillator pads and the battery pack is inserted ready to be used in an emergency)
Temperature: 0°C~ 43°C (32°F ~ 109°F)
Humidity: 5% ~ 95% (non condensing)
Altitude 0 to 15,000 feet (operational and storage)
Drop Withstands 1.2-meter drop to any edge, corner, or surface
Vibration Operating: Meets MIL-STD-810G Fig.514.6E-1, random
Standby: Meets MIL-STD-810G Fig.514.6E-2, swept sine (helicopter)
Sealing IEC 60529: IP55
ESD Meets IEC 61000-4-2:2001
EMI (Radiated) Meets IEC 60601-1-2 limits, method EN 55011:2007 +A2:2007, Group 1, Class B
EMI (Immunity) Meets IEC 60601-1-2 limits, method EN 61000-4-3:2006 +A1:2008 Level 3 (10V/m 80MHz to 2500MHz)
   
Defibrillator
Category Nominal Specifications
Operating Mode Fully-automatic or Semi-automated
Waveform e-cube biphasic (Truncated exponential type)
Output Energy 150 J at 50 Ω  load for adults
50 J at 50 Ω load for children
Charge Control Controlled by an automated patient analysis system
Energy Storage 10 seconds, typical. Using new disposable LiMnO2 battery pack (at 20°C)
Charging Time 11 seconds, typical. Using new disposable LiMnO2 battery pack, depleted by 15 discharges at 200 Joules per discharge (at 20°C)
Time from CPR to Shock Less than 6 seconds from the completion of CPR to shock delivery
Discharge The device performs a self-discharge in the following events:
When the patients ECG changes to a rhythm that does not require defibrillation.
When the device is turned off by pressing the Power Button for at least a second.
When the pad is detached from the patients body or the pad connector is detached from the device.
When the impedance of the patient is out of the range of defibrillation (25 Ω ~ 175 Ω)
(Semi-automatic only) When the shock button is not pressed within 15 seconds from the completion of the charge.
Fully-Automatic Shock Shock is automatically delivered if a shockable rhythm is detected
iPADSP1 Cardiac ScienceG3 Philips/LaerdalFR3 ZOLLAED Plus PhysioControlLifepak CR+ HeartsineSamaritan
sp1_frontpage powerheart-g3-plus-aed philipsfr3 AEDPlus_Front_trans-269x300 lifepak-crplus image

Electrodes Tested For Presence

tick

tick

tick

tick

cross

cross

Daily, Weekly, Monthly Self Tests

tick

tick

tick

tick

tick

tick

All Tests Automated

tick

tick

tick

tick

tick

tick

Status Indicator Showing Clinical Readiness

tick

tick

tick

tick

tick

tick

Battery Capacity Gauge

tick

tick

cross

cross

cross

cross

Pad Life Indicator

tick

cross

cross

cross

cross

cross

Used Pad Detection

tick

tick

cross

cross

cross

cross

Pad Life From
Manufacture

36 Months

24 Months

24 Months

5 Years

24 Months

3.5 Years

Uses Same Set of Pads of Adult And Child

tick

cross

tick*

cross

cross

cross

Ambient Noise Detector

tick

cross

cross

cross

cross

cross

Integrated Pad Storage

tick

tick

cross

tick

tick

tick

CPR Detection

tick

cross

cross

tick

cross

cross

Illuminated Prompts

tick

cross

tick

tick

tick

tick

Internal Memory
Capacity

15 Hours

1 Hours

8 Hours via memory card

7 Hours

20 Minutes

45 Minutes

Data Transfer Method

IR / SD Card

Direct Connect

Direct Connect

Direct Connect

IR

Direct Connect

User Reprogrammable

tick

tick

tick

tick

cross

tick

CPR Metronome

tick

tick

tick

tick

cross

tick

Paramedic Handover Information

tick

cross

cross

cross

cross

cross

Fluid Ingress Protection

IP55

IP24

IP55

IP55

IP55

IP56

Battery Capacity (Shocks/Shelf)

200/5 Years

290/5 Years

/5 Years

/5 Years

/2 Years

/3.5 Years

Carry Case Supplied As Standard

tick

cross

cross

tick

tick

tick

Manual Self Test Option

tick

cross

cross

tick

cross

cross

All Status Indicators Visible When Case Is Closed

tick

tick

cross

cross

cross

cross

*With Key

The iPAD SP1 defibrillator is deigned with the end user in mind, making it as simple as possible to use.  It’s modern and attractive exterior houses state of the art technology that saves precious seconds when every second counts.  It is a high quality, robust device and yet it is has been well received for its lightweight compactness in comparison to older technology.

In operation, the iPAD SP1 intelligently guides users with a series of  large, clear illustrations which illuminate to emphasise key commands.  This is coupled with calm voice prompts giving instructions at every step.  Importantly, the voice prompts automatically adjust to background noise, up to 90 decibels. This can be crucial when background noise escalates or in challenging environments when sudden cardiac strikes.  Equally, this is has proven useful in a busy training environments.

Should the need arise for a defibrillator to be used on a child, the iPAD SP1 is equipped with pre-connected electrode pads that can be used on both adults and children.  On the front of the device there is a switch.  By simply lifting a clear cover over the switch (designed to prevent accidental switching) the switch can simply be moved across to select “paediatric mode” . This saves the time, worry and  expense of having to change to a different set of pads or adjusting other settings.

Importantly the iPAD defibrillators are fully pad compatible with the defibrillators carried on front line NHS Ambulances.  A simple plug-in adapter saves pad changes when backup arrives.  This improves patient care, saves precious time and saves costs.

Widely used by the NHS Ambulance Service, the Emergency Services & in Public Access schemes, community projects & commercial organisations.

LATEST NEWS